ตะกร้าสินค้า
/

Simplus Vacuum Cleaner CMYH007 User Manual

Simplus Vacuum Cleaner CMYH007 User Manual

Ⅰ. Product Parameters

Product Name

Model No.

Rated Voltage

Input power 

Rated Frequency

Vacuum Cleaner

P872

220-240 V

350W

50/60Hz

 

Ⅱ. Product Illustration

 

① Dust Cup Assembly

② Switch Button

③ Dust Cup Release Button

④ Main Unit Handle

⑤ Power Cord

⑥ Roller Brush Button

⑦ Safety Roller

⑧ Roller Brush Assembly

⑨ UV Lamp Group

⑩ Air Outlet

 

Ⅲ. Usage Instructions

  1. Plug the power cord plug into the socket to connect power, and press the switch button on the main unit to start the machine.

①Power Button

 

  1. Place the machine on the item to be cleaned (e.g., bed), and push and pull it slowly back and forth for cleaning. (It is recommended to clean at a speed of less than 20 seconds per meter, back and forth three times).

3. Aromatherapy Disc Installation Guide

① Remove the dust cup

② Take out the filter pad, open the lid, and insert the aromatherapy disc

③ Close the lid to complete placement

 

Notes:

The machine is equipped with a safety protection function: when the machine is lifted too high, the sterilization lamp function stops.

The roller has a stall protection to avoid winding objects.

Adjust the height between the machine and the contact surface during use to ensure normal operation. If the UV lamp does not work when lifted too high, it is a normal response.

 

Ⅳ. Cleaning Tutorial

Warning:

Ensure the machine is turned off and the power plug is unplugged before cleaning!

Use original parts only, otherwise the warranty service may not be applicable.

 

  1. Turn off the machine and unplug the power plug.
  2. Press the dust cup release button as shown, and the dust cup assembly will pop out automatically.

①Dust Cup Release Button

 

  1. Press the filter lower cover button to remove the filter upper cover.

①Filter Lower Cover Button

 

  1. Remove the filter assembly and take out the HEPA.

① Filter Assembly

② Dust Cup Assembly

③ Filter Screen

④ HEPA

 

5.The roller has strong power during operation, and hair may adhere after long-term use. It needs to be taken out and cleaned regularly: first turn off the power, press the roller button, and remove the roller for cleaning.

6.When cleaning the dust cup, pour out the dust, wash components such as the filter screen and HEPA, and ensure they are completely dry before reuse.

 

Tips:

1.It is recommended to clean the dust cup and filter element after each use. When the dust cup is full, please clean it in a timely manner, otherwise the usage effect will be affected.

2.After washing, all components must be fully dried before being reinstalled for use, as failure to do so may damage the product.

 

Ⅴ. Precautions

When using this product, follow the basic warnings below:

Never look directly at the lit UVC+UVA ultraviolet lamp with your eyes to avoid injury.

 

  1. UVC+UVA ultraviolet rays can harm the skin and eyes of humans and animals. Do not directly irradiate humans, plants, or animals.
  2. Perform a local test on the object to be sterilized and purified first to avoid damage to light-sensitive or non-UV resistant objects.
  3. Do not intentionally damage the roller (safety switch) at the bottom of the product, as this will cause the UV lamp to lose protection.
  4. Do not intentionally touch the conductive female plug of the handheld anti-mite vacuum to avoid electric shock risk.
  5. Do not leave the anti-mite vacuum plugged in when unattended. Unplug the power when not in use or before maintenance.
  6. To reduce the risk of electric shock, do not use it outdoors or on wet surfaces.
  7. Use this product as specified in the manual. Only use the functions recommended in the manual.
  8. Do not use the product if the plug or power cord is damaged. If the product is dropped, damaged, exposed to the outdoors, or falls into water, or fails to work, send it to a service department for repair.
  9. This product is for general household use only, not for commercial or other purposes.
  10. Avoid sucking sharp hard objects such as glass shards and screws, as well as construction waste, to prevent damage to the machine.
  11. Do not use the power cord as a handle, or pull the power cord against sharp edges. Do not place the anti-mite vacuum on a hot surface.
  12. Do not use the product when any air duct is blocked, as this may damage the motor. When storing, keep it away from dust, lint, hair, and any substances that may block or reduce air flow.
  13. Keep hair, clothing, mobile phones, and any parts of the body away from the openings and moving parts of the anti-mite vacuum.
  14. Turn off the machine switch before unplugging the power plug.
  15. Disconnect the machine power before connecting accessories.
  16. Do not suck any burning or smoking objects, such as cigarette butts, matches, or hot ashes.
  17. Do not use the product when the dust bucket or filter is not installed, as this may damage the motor.
  18. If the power cord is damaged and needs to be replaced, it must be done by a professional or designated maintenance point. Do not disassemble it (without authorization) to avoid danger.
  19. All daily maintenance and servicing must be performed after unplugging the machine's power plug.
  20. Regularly clean the garbage in the dust bucket to avoid machine failure.
  21. Do not clean the machine surface with gasoline or oily substances. Use a soft cloth or neutral detergent. Wring out the cloth and do not let water penetrate into the machine's electrical components.
  22. Bundle the power cord and store it together with the machine.
  23. Keep the storage area dry.
  24. Do not stack heavy objects on top of the machine.

 

Special Tips:

 

  1. This product is not suitable for persons with physical, cognitive, or mental impairments, or those lacking knowledge and experience (including children), unless used under the supervision of a responsible person.
  2. Do not allow children to play with this product.

 

Ⅵ. Common Issues

When encountering the following general issues, users can troubleshoot them independently:

Caotion:When the following issues are found, please turn off the switch immediately to prevent damage to the machine and other hazards:

Problem Phenomenon

Possible Cause

Solution

Cannot start up

Plug not inserted properly

Reinsert the plug and ensure it is firmly in place

Socket has no power

  Switch to another socket

Machine is damaged

  Replace with a new machine

Unusual noise from product  

Dust cup is full or air duct blocked

Empty the dust bucket and clear the blockage

Reduced suction ability  

Dust cup is full or filter is dirty

  Clean the dust bucket and wash the filter (do not install a wet filter to avoid motor damage)

Unstable voltage

Wait until the voltage stabilizes

Dust blowing out during use

 

Filter device in dust bucket is damaged  

Stop using immediately and replace the filter

Filter not installed

Stop using immediately and install the filter properly

UV lamp not working

 

Safety switch (small roller) not in contact with the surface

The UV lamp only works when the bottom of the product is in contact with the surface

UV lamp is damaged

  Replace the UV lamp

Internal components are damaged  

Repair or replace components

Patting function not working

 

Wire terminals/wires are disconnected

Reconnect the terminals/wires and ensure they are firmly in place

Internal circuit components are damaged

  Repair or replace components

Patting motor is damaged

Repair or replace the motor